BeamClamp Location Plates and Bolt Lengths - BY

Overview

Note: Cap/End plate thickness will vary based on the design code followed, the flange width of the applicable beam and the type of load acting on the connection.

Please contact a structural engineer for further details.

 

 

 

 


Technical Specifications

Diagram - Location Plates - BY
Diagram - Location Plates - BY
Dimension table for location plates to suit BY & BZ products
Bolt
dia.
Bolt
grade
A (in)
Upper beam
width +
B (in)
Lower beam
width +
C (in)
Upper beam
Min. width +
D (in)
Lower beam
Min. width +
H (in)
Dia.
T (in)
Min.
1/2 A325/Grd.5 9/16 9/16 3-3/4 3-3/4 9/16 1/2
1/2 A490 9/16 9/16 3-3/4 3-3/4 9/16 1/2
5/8 A325/Grd.5 11/16 11/16 4-5/8 4-5/8 11/16 5/8
5/8 A490 11/16 11/16 4-5/8 4-5/8 11/16 5/8
3/4 A325/Grd.5 13/16 13/16 5 5 13/16 3/4
3/4 A490 13/16 13/16 5 5 13/16 1

Thickness of clamps (Dim X)
Bolt
Dia.
Type
BY (X)
Type
BZ (X)
Type
BY + BYP (X)
1/2 1/2 1-1/8 15/16
5/8 11/16 1-5/16 1-3/16
3/4 7/8 1-5/8 1-7/16

Thickness of nut & washer (Dim N)
Bolt Dia. N
1/2 5/8
5/8 13/16
3/4 15/16